Differential interference contrast microscopy

Looking at samples under a microscope that are unstained typically shows nothing. Without a stain to show the sample, most specimens would look invisible and transparent. However, one technique that has been used in microscopes for a very long time is called differential interference contrast (DIC) microscopy and is dependent on a very simple principle. There have been many other methods to make it more quantitative but it is first important to understand how this works.

In one line, the method translates the changes in phase (invisible to the human eye) to amplitude which is visible to the human eye. The method is especially sensitive to the rate of change across the length. Thus long flat surfaces such as the flat surface of the cytoplasm do not generate as much contrast as would sharp gradients that are presented by smaller vesicles.

In the microscope, two identical light beams are generated that are polarized. These two beams are then separated by a small distance and transmitted through the sample. A small phase lag is then introduced into one of the sample light beams. These two beams of light then interfere with one another in the image plane that is seen by the observer.

The images from the DIC microscope appear almost three dimensional and generate contrast where none was seen before. See more images at the link below with a comparison of phase contrast with DIC.

Similar Posts

  • Malaria games

    We think that image processing problems are difficult and interesting but there are others that elude us all the time. Malaria, a mosquito borne illness affects nearly 600,000 patients per day. The diagnosis unfortunately in many countries still uses the traditional Giemsa stain of blood. This requires a pathologist to study the slides and then…

  • Micro-Microscope

    Cell phone camera’s are small. However, typically microscopes are large bulky devices that have large lenses to collect light and are used for getting high resolution magnified images that are coupled to bulkier high sensitivity camera’s. But what about in-vivo microscopy where the animal needs to be brought below the microscope to focus. The laboratories…

  • 3D Scanning

    There are many ways to scan in 3D and there are many uses for scanning in 3D. One of the major ones has been geology and civil engineering. Imagine when you are making roads, the one thing that you require is the lay of the land. This will enable the building of roads that is…

  • Elastomer for surface imaging

    Surface geometry made easy It is extremely difficult to measure the cell surface topology using microscopes or camera’s. Typically, the choice is to use reflected light, refracted light or some unique modification that requires light to enter at correct angles, be altered and then measured with the camera. Typically, setup like that cost hundreds to…